AA-IOT-SOM-104
IoT Enabled Addressable Control Module
Intelligent Building System Interface with IoT Monitoring
The Airlight AU-IoT-SOM-104 is an IoT-enabled addressable single output control module designed to interface fire alarm systems with electromechanical devices and building automation systems. This intelligent relay module transmits real-time activation status, relay operation data, and device health information to the fire alarm control panel which is seamlessly uploaded to the cloud via internet connectivity. Designed to control critical building systems during fire emergencies including evacuation support systems, AHU (Air Handling Unit) tripping, security access control deactivation, and firefighting system activation, it provides reliable interface between fire detection and building response systems. Powered directly by signaling line circuit, it eliminates need for separate power wiring while providing continuous electrical supervision. The addressable capability with soft addressing enables flexible device ID configuration remotely from control panel without physical switches. IoT connectivity enables remote monitoring of all relay activations, operation verification, response time tracking, and comprehensive system integration diagnostics, empowering facility managers to ensure building system coordination and maintain emergency response readiness from any location worldwide.
IoT & Smart monitoring Capabilities
Real-Time Operation Monitoring & Cloud Upload: Continuously monitors relay status, activation commands, and connected device responses. All relay operations, activation timestamps, duration, and electrical parameters automatically transmitted to control panel and uploaded to cloud for remote monitoring.
Intelligent Event Alerts: Instant cloud-based notifications for relay activation, connected device status changes, electrical supervision failures, connectivity issues, and maintenance requirements. Multi-channel alerts ensure rapid awareness of building system coordination during emergencies.
Remote Testing & Verification: Conduct remote functional tests of relay operation and connected device response without physical site access. Verify control outputs, electrical supervision, and building system integration from centralized monitoring center for proactive maintenance.
System Integration Analytics: Cloud-based analytics track relay activation patterns, building system response times, operation frequency, and coordination performance. Historical data enables emergency procedure optimization and identifies system integration issues before they affect life safety
Remote Access & Management: Facility managers and building automation teams can monitor control module status, verify relay operations, track building system response, and access historical activation records through web-based platforms and mobile devices from any location worldwide.
Proactive Device Health Monitoring: IoT-based continuous monitoring of relay contacts, electrical circuits, connected device loads, and addressable communication. Predictive maintenance alerts identify potential failures before they affect emergency building system control capability.
Building System Comtrol Applications
Evacuation Support Systems: Controls elevator recall, door release mechanisms, emergency exit unlocking, and stairwell pressurization systems. Ensures safe evacuation routes are accessible and properly configured during fire emergencies for occupant safety.
Security Access Control Deactivation: Overrides electronic access control systems during fire emergencies to ensure all exit routes are accessible. Unlocks magnetic locks, releases turnstiles, and opens security barriers for unimpeded emergency egress.
Smoke Control Systems: Activates smoke exhaust fans, opens smoke vents, controls dampers, and manages smoke control systems. Coordinates building smoke management for improved visibility during evacuation and firefighting operations.
AHU (Air Handling Unit) Shutdown: Automatically trips air handling units to prevent smoke spread through HVAC systems. Coordinated shutdown of ventilation systems prevents fire and smoke migration to unaffected building areas, containing hazards and protecting occupants.
Firefighting System Activation: Triggers suppression systems, activates fire pumps, opens deluge valves, and initiates pre-action sprinkler systems. Coordinates automatic firefighting equipment operation for rapid fire suppression and containment.
Emergency Lighting & Power: Switches emergency lighting circuits, activates backup generators, transfers critical loads to emergency power, and controls emergency illumination systems for safe evacuation route visibility.
Advanced Technical Features
Soft Addressing Configuration: Digital soft addressing enables easy device ID configuration remotely through control panel without physical DIP switches or programming tools. Flexible addressing simplifies installation, system modifications, and device replacement procedures.
Visual LED Supervision: Blinking green LED during normal scan provides visual confirmation of operational status and addressable communication. Steady red LED during activation indicates relay operation for easy on-site verification and troubleshooting.
Electrical Supervision: Continuous monitoring of input circuits, relay contacts, and connected device loads ensures system integrity. Automatic detection of open circuits, short circuits, and wiring faults with instant reporting to panel and cloud.
1A Relay Contact Rating: Relay contact rated at 1A @ 24V DC provides reliable control of electromechanical devices, contactors, and building system interfaces. Adequate capacity for most building control applications with proven long-term reliability.
Remote ID Configuration: Device ID can be changed remotely from control panel without physical access to module. Enables flexible system reconfiguration, device replacement, and addressing changes without on-site programming visits.
Ideal Applications
- Access Control Integration: Magnetic lock release, turnstile control, security barrier override during emergencies
- Elevator Control: Elevator recall to designated floors, car door release, emergency operation mode activation
- Fire Suppression Systems: Pre-action system activation, deluge valve control, fire pump start signals
- Emergency Lighting: Emergency lighting circuit switching, backup generator start, power transfer controls
- Door & Exit Control: Emergency exit door unlocking, stairwell door release, fire door hold-open release
- Smoke Management: Smoke exhaust fan activation, smoke damper control, pressurization system operation
- Building Management Systems: BMS interface for coordinated emergency response and facility system integration
- Industrial Equipment: Process shutdown, gas valve closure, industrial equipment emergency stops
- Communication Systems: Mass notification activation, emergency paging system triggers, intercom coordination
Relay Contact Rating: 1A @24V DC
Storage temperature : -10ºC to 60ºC