AU101SD

Addressable Intelligent Smoke Detector

This device intended to be used for addressable automatic fire detection system to detect presence of smoke for fire warning. This device measures the smoke level in protected areas and analyses the level of smoke and verify with alarm level setting. When smoke level crosses the set level, it communicates to fire warning system control panel along with its ID. Alarm activated sensor, continuously interacts with control panel to update the real time smoke level exists at reported location. If smoke level rises, action can be taken accordingly. Similarly if it gets reduced, action can be taken for normalcy by rescue staff. The Smoke sensor works on photoelectric principle. Main sensor component is special LED to illuminate the smoke chamber. This LED illumination level gets reduced due to its aging. Hence its sensitivity may go out of sensitivity range. Therefore it requires a periodical calibration to ensure its functional objective. Refer IS 2189 for more details.

SMOKE SENSITIVITY SETTINGS

Standard smoke level for alarm is set at the factory. According to the area of protection, this setting can be changed from the control panel by the user.

SOFT ADDRESSING:

 Based on the order, the address of the sensor is configured at the factory. If an alteration in the address is required, it can be changed from the control panel. No extra special tools are required.

REMOTE TESTING

The various functional validations manually from the remote control panel can be done for maintenance and troubleshooting. If the control panel is connected to the cloud, it can be accessed through the internet/mobile app.

DETACHABLE DETECTOR

A detector designed to be easily removed from its normal operating position for maintenance and servicing purposes.

INSECT MESH

The smoke chamber vent is covered using anti-corrosive metal mesh to prevent the entry of insects.

ENVIRONMENTAL TYPE TESTING

The detector environmental type tested, as per IS 11360, UL 264N with NABL India and NABL USA.

SMOKE DETECTOR CALIBRATION

As per IS 2189/ NBC 2016 Smoke detector being a measuring instrument and the sensitivity is vulnerable to get reduced, hence periodical calibration is required. Our factory is located in Chennai, India. We undertake calibration services for our make sensors and certify them. The certificate is mandatory to be maintained for the government and third-party audits. 

fire alarm & talkback with pa products
  • Fire alarm, public address, and talkback system Control panel-2 Loop
  • Fire alarm, public address, and talkback system Control panel-3 Loop
  • Fire alarm, public address, and talkback system Control panel-4 Loop
  • Fire alarm, public address, and talkback system Control panel-5 Loop
  • Fire alarm, public address, and talkback system Control panel-6 Loop
  • Networkable Fire alarm, pubic address system With talkback system control panel-2 Loop
  • Networkable Fire alarm, pubic address system With talkback system control panel-3 Loop
  • Networkable Fire alarm, pubic address system With talkback system control panel-4 Loop
  • Networkable Fire alarm, pubic address system With talkback system control panel-5 Loop
  • Networkable Fire alarm, pubic address system With talkback system control panel-6 Loop

others in series

Addressable Intelligent Heat Detector

Model No: AA103HD

Addressable Intelligent Multisensor

Model No: AU101MD

Addressable Intelligent Multisensor With Speaker

Model No: AA105MDS

Addressable Intelligent Duct Smoke Detector

Model No: AU101DSD