AA104CP
Addressable Manual call point
Addressable manual call point designed to detect manual activation and automatically communicates to fire alarm control panel along with its ID to take appropriate action as programmed. Advantage of this unit is clear visibility with the dual LED indication and it has the large size dimension.
fire alarm & talkback with pa products
- Fire alarm, public address, and talkback system Control panel-2 Loop
- Fire alarm, public address, and talkback system Control panel-3 Loop
- Fire alarm, public address, and talkback system Control panel-4 Loop
- Fire alarm, public address, and talkback system Control panel-5 Loop
- Fire alarm, public address, and talkback system Control panel-6 Loop
- Networkable Fire alarm, pubic address system With talkback system control panel-2 Loop
- Networkable Fire alarm, pubic address system With talkback system control panel-3 Loop
- Networkable Fire alarm, pubic address system With talkback system control panel-4 Loop
- Networkable Fire alarm, pubic address system With talkback system control panel-5 Loop
- Networkable Fire alarm, pubic address system With talkback system control panel-6 Loop
- Soft addressing
- Electrical supervision
- Transient voltage protection up to 2.4KV
- No manual reset is required
- Address can be changed from panel
- Flip cover to avoid accidental activation
- Blinking LED for visual supervision
- Remote test facility from the panel
- Attention seeking product design for easy identification
With Backbox: 378g
What is a Manual Call Point?
Manual Call Points (MCP) are devices that are used to manually trigger the fire alarm system. It is to be used only after the confirmation of the existence of fire in the building. They can also be used at the time of other potential threats such as terrorism, earthquakes, etc. to alert the occupants for immediate evacuation.
Where & how should Manual Call Points be installed?
MCPs should be installed at exit-prone areas of the building that include staircases, escape routes, against main doors and corridors.
They should be positioned such that no person travels beyond 12 meters to activate the nearest call point. Or, there should be a maximum gap of 24 meters between the two nearest call points.
They should also be mounted at a height of about 1.5 meters from the floor to ease actuation.
What are the variants of Manual Call Points?
- Push Button type: Actuated by pushing the button. These are mostly used indoors of office space, residences, etc., and often come with a protective flip cover to avoid malicious activation.
- Break Glass type: They are triggered by breaking the glass and pushing the inside button, or by just breaking the glass. These can be used indoors at industries, residences, etc.
- Explosion Proof type: Mostly found suitable for outdoors or industrial purposes. It is actuated by breaking the glass.
- Weatherproof type: Again a suitable variant for outdoors and industrial applications. They are triggered by breaking the glass.
others in series
Addressable Weather Proof Manual Call Point
Model No:AA103WCP
Addressable Flame Proof Manual Call Point
Model No:AA103FCP