AA-IOT-CP-104

IoT Enabled Addressable Manual Call Point

Intelligent Manual Fire Alarm with IoT Intelligence:

The Airlight AA-IoT-CP-104 is an IoT-enabled addressable manual call point designed for manual fire alarm activation with cloud-connected monitoring capabilities. This intelligent device transmits real-time activation events, precise location data, and operational status to the fire alarm control panel which is seamlessly uploaded to the cloud via internet connectivity. Designed in full compliance with NBC 2016 and international standards (UL 38, EN 54-Part 11), it features bold, highly visible design ensuring easy identification from long distances. The aesthetic design aligns cohesively with other Airlight fire alarm devices including Talkback Speakers and Speaker Beacons for unified system appearance. The protective flip cover is crafted from strong, transparent polycarbonate ensuring durability while maintaining visibility. Featuring large, prominent push button with electronic latch circuit, the device requires no extra key for resetting—remote reset capability from control panel eliminates manual intervention. Dual redundant LEDs provide synchronized blinking during scan and steady glow during alarm for enhanced reliability. IoT connectivity enables remote monitoring of all activations, location tracking, response time analysis, and comprehensive system diagnostics, empowering facility managers to verify emergency response procedures and maintain system readiness from any location worldwide.

 

IoT  & Smart monitoring Capabilities

Real-Time Activation Monitoring & Cloud Upload: Every manual activation is instantly transmitted to control panel with precise device location, timestamp, and activation context. All events automatically uploaded to cloud for remote monitoring, compliance documentation, and emergency response analysis.

Intelligent Event Alerts: Instant cloud-based notifications for manual activation, precise location identification, device status changes, connectivity issues, and maintenance requirements. Multi-channel alerts ensure rapid awareness and coordinated emergency response capability.

Activation Pattern Analytics: Cloud-based analytics track activation frequency, response times, drill performance, false alarm patterns, and system usage by location. Historical data enables emergency procedure optimization, training needs identification, and false alarm reduction strategies.

Remote Access & Management: Facility managers and emergency response teams can monitor all manual call point activations, track response times, verify alarm procedures, and access historical activation records through web-based platforms and mobile devices from any location worldwide.

Precise Location Tracking: IoT-enabled location identification instantly displays exact call point position on control panel touchscreen and cloud dashboard. Emergency responders can immediately identify activation location and navigate to precise area for rapid response and investigation.

Remote Reset Capability: Electronic latch enables remote reset from control panel without physical key access. IoT connectivity allows authorized personnel to reset devices remotely after incident verification, eliminating on-site visits and enabling faster system restoration to normal operation.

Bold Design  Enhanced Visibility

Transparent Protective Cover: Flip cover manufactured from strong, transparent polycarbonate material provides robust protection against accidental activation while maintaining excellent visibility. Durable construction withstands repeated operation and environmental exposure without yellowing or cracking.

Cohesive System Appearance: Aesthetic design aligns seamlessly with other Airlight fire alarm devices including Talkback Speakers, Speaker Beacons, and detectors. Unified design language creates professional, cohesive appearance throughout facility for enhanced brand consistency and visual appeal.

Dual Redundant LEDs: Two independent LEDs provide enhanced reliability and visibility. LEDs blink synchronously during normal scan operation, ensuring operational status verification from multiple viewing angles. Dual-LED redundancy ensures continued indication even if one LED fails.

Large Prominent Push Button: Oversized push button with clear tactile feedback ensures easy activation even during panic situations or when wearing gloves. Intuitive operation requires no special training—anyone can activate alarm quickly during emergency.

High-Visibility Alarm Indication: During alarm activation, dual LEDs provide steady glow for clear, immediate visual feedback confirming successful alarm initiation. Enhanced visibility ensures occupants understand alarm has been activated and emergency response is underway.

 

 Advanced Electronic Latch System

Electronic Latch Circuit: Advanced electronic latching mechanism maintains alarm state until deliberately reset. No mechanical components to wear out or fail over time. Electronic design ensures reliable latching performance throughout extended service life.

Cloud-Based Reset Logging: All reset operations automatically logged with timestamp, user identification, and reset reason. Cloud storage provides complete audit trail for compliance verification, insurance documentation, and emergency procedure review.

Keyless Remote Reset: Eliminates traditional mechanical key requirement for reset operations. Authorized personnel can reset devices remotely from control panel after alarm investigation and clearance, streamlining post-incident procedures and reducing operational downtime.

Simplified Maintenance: Electronic latch eliminates need for spare keys, key management procedures, or lock maintenance. Remote reset capability reduces maintenance visits and associated labor costs while ensuring faster system restoration after activations.

Ideal Applications

  • Commercial Buildings: Offices, retail spaces requiring NBC-compliant manual fire alarm activation points
  • High-Rise Residential: Apartments and condominiums with fire safety manual activation requirements on each floor
  • Healthcare Facilities: Hospitals, clinics requiring manual alarm points for staff-initiated emergency response
  • Educational Institutions: Schools, colleges with manual call points for fire drill procedures and emergency activation
  • Hotels & Hospitality: Properties requiring manual alarm activation points in corridors, stairwells, and public areas
  • Industrial Facilities: Manufacturing plants, warehouses with manual emergency alarm activation requirements
  • Shopping Malls: Large retail complexes requiring strategically placed manual fire alarm activation points
  • Transportation Hubs: Airports, metro stations, bus terminals with manual emergency alarm requirements
  • Parking Facilities: Multi-level parking structures requiring manual fire alarm activation capability
  • Exit Routes: Stairwells, corridors, exits requiring manual alarm activation per building codes